Engineering
Substation EPC engineering, BESS EPC engineering, P&C, and SCADA design, engineered to commission and energize without surprises in compressed windows.
Engineering
Submit your request online and our team will quickly assess the situation and coordinate the right support for your site. Or call us directly for immediate assistance.
The form could not be loaded. Please try again later.
Electrical infrastructure for mission critical facilities.
Substations built and energized by the same team that engineered it.
Substation design to IEEE C37 and IEC 62271. 25 kV to 500 kV, greenfield and brownfield.
Engineering, P&C, SCADA, civil and structural, electrical work packages.
Pads, access roads, foundations, steel structures, transformer and switchgear install, control buildings, IEEE 80 grounding, telecom.
Interconnection studies, applications, ESA packages, and regulatory documentation engineered for first-submission approval.
The team that engineers the substation performs the testing and energization. No handoff between design and commissioning.
For data center operators using storage for grid services, peak shaving, or backup support, Spark engineers, procures, builds, commissions, and maintains the system under one accountable team.
Custom technical and field engineering, OEM-direct procurement, P&C design, civil and electrical install, field testing, and commissioning.
Cold commissioning, PCS power-up (AC first, then DC), grid sync, OV/UV protection, frequency ride-through, and firmware validation.
BMS, EMS, and PCS integration with round-trip efficiency and capacity testing engineered for mission-critical duty cycles.
Experience with all major BESS OEMs and the major inverter platforms.
1 GW+ of BESS systems serviced; 2+ GWh BESS under long-term service agreement.
24/7 emergency support and preventive and corrective maintenance from one accountable team.
Data center schedules live or die on interconnection approval timing. Spark prepares studies, ESA packages, and utility applications engineered for first-submission approval, then carries the same scope into physical execution and substitution risk management.
Load flow, short-circuit, protective device coordination, harmonics, and EMT studies for interconnection approval.
ESA package preparation, utility applications, and regulatory documentation engineered for compressed schedules.
Protection and control philosophy, IED programming, and interconnection-specific relay settings written for the utility.
Direct coordination with utility transmission operators and ISOs: IESO, AESO, ERCOT, MISO, and PJM.
Power system reliability studies and N+1 and 2N redundancy validation for mission-critical loads.
Owner-furnished equipment management with substitution risk held by Spark, not transferred to the Owner.
Spark Power covers all 50 U.S. states and Canada.
Acceptance testing to NETA ATS standards for new and refurbished utility substation and distribution equipment.
Predictive and preventive maintenance to NETA MTS standards across utility transmission and distribution fleets.
Low-, medium-, and high-voltage breaker testing with primary and secondary injection.
Oil analysis, DGA, insulation resistance, power factor, and sweep frequency response on critical transformers.
Thermography, power quality monitoring, corona studies, and partial discharge analysis.
Audit-ready documentation aligned with NERC PRC-005 in compressed outage windows; 24 to 72-hour mobilization.
Real questions,
Spark Testing (Canada and U.S.) is NETA-accredited and performs acceptance testing, predictive maintenance, breaker and relay testing, transformer diagnostics, and full commissioning protocols.
Yes. Independent third-party QA/QC and commissioning oversight is a core Spark Testing offering — FAT review, SAT, pre-energization inspections, P&C verification, and full functional performance testing.
Disciplined outage coordination, pre-outage walkdowns, switching plans, and commissioning sequences. Zero unplanned downtime during planned maintenance and commissioning activities across mission-critical facilities. Audit-ready documentation aligned with NERC PRC-005 in compressed outage windows.
Within 24 to 72 hours for emergency response, dispatched from 16+ regional offices across Canada and the U.S.
Yes. Greenfield and brownfield substation EPC up to 500 kV, with stamped engineering in 27 U.S. states and 8 Canadian provinces. ISO 9001 certified for High Voltage Eastern Canada and Spark Renewable Services in the U.S.
Yes. Full system functional performance testing including redundancy validation is standard in Spark’s commissioning protocols.
Yes. Spark routinely works inside bank/firm-owned data center environments with the discipline that audited financial-services facilities require.
The form could not be loaded. Please try again later.